Hello. Weintek HMI is one of the most commonly used HMIs on the market. Low price, variety, good quality, easy-to-use software, and support for most popular connections today are the advantages of HMI Weintek.
Today plc247.com will use HMI Weintek MT8071iE to control Siemens Sinamics V20 inverter via Modbus RTU (using built-in RS485 port in both HMI and VFD)
Weintek MT8071iE & Sinamics V20 “Wiring Diagram”

Siemens V20 Modbus RTU Configuration
In addition to the basic parameters installed according to the motor (frequency, current, voltage…) we need to set the communication parameters as follows

Sinamics V20 Registers Address for Control

Note: Weintek MT8071iE Modbus Address
= “VFD Address (dec) +1”
>>> Motor Control Address = 99 + 1 = 100
+ Set Word 100 = 1151 >>> Forward Run
= 3199 >>> Reverse Run
+ Set Word 100 = 1150 >>> Stop
+ Set Word 100 = 1278 >>> VFD Reset
>>> Frequency Reference Address = 100 + 1 = 101
Sinamics V20 Registers Address for Monitoring


HMI Weintek Modbus RTU Setting
We need to set the same Mobdus communication parameters as set in Sinamics V20 VFD

HMI Programming
+ Main Control Panel

+ VFD “Ready Run”

+ VFD “Running”

+ VFD “Alarm”

+ VFD “Reset Command”

+ Setting Frequency

+ Forward Run

+ Reverse Run

+ Stop Command

+ Output Frequency

+ Output Current

+ Output Voltage

+ Output Speed

Video Tutorial
======
Related Software and Documents
- Download HMI Weintek Programming Software
- Download Siemens Sinamics V20 Manual PDF (Password Extract: plc247.com)
If in the process of connecting Weintek MT8071iE with Sinamics V20 you encounter any difficulties, please comment below the article, plc247.com will reply to you as soon as I read it.
Best Regards!

Hola, tengo los mismos dispositivos e intento leer y modificar la frecuencia del sinamics v20 pero me dice error de comunicación la pantalla. Hice todas las configuraciones de manual y siempre tengo el mismo resultado. Anteriormente leía los datos con un PLC M221 schenider pero también dejo de funcionar, que pudo haber pasado?
sir please comment via english
Hi
How can connect hmi weintek and plc 1200 siemens through rs 485 (not ethernet)?
Siemens 1200 with cm1241 communication module?
yes, you can using CM1241 module