Hello everyone!
PLC Mitsubishi FX3U and Servo Motor Yaskawa Sigma-7 are two extremely popular devices used in many machines around the world, especially machines from Japan.
Today plc247.com will guide you to use the FX3U PLC to control Yaskawa Servo in the simplest and easiest way.
FX3U & Yaskawa Sigma 7 “Connection Diagram”

+ Use resistor R = 2K2 (Ohm) to reduce voltage “24 VDC to 5 VDC”
I/O Address
+ Input
- X0: ORG Sensor
- X1: Forward Limit Sensor
- X2: Reverse Limit Sensor
+ Output
- Y0: Pulse Output
- Y4: Direction Output
- Y5: Servo ON/OFF
Yaskawa Sigma Servo Parameters Configuration
For the Yaskawa Sigma 7 Servo, we need to set the main parameters as follows
- Pn200.0: “Reference Pulse Form”
plc247.com uses 1 pulse control mode (Pulse + Direction)
>>> Select “0: Sign + Pulse, positive logic”
- Pn200.3: “Filter Selection”
>>> Select “1: Uses reference input filter for open collector signal (to 200kpps)”
- Pn20E + Pn210 + Pn212
Three parameter is used to set the number of pulses for 1 revolution of the motor

In this Project plc247.com use “Ball screw leed = 5mm” & ” 1PLS = 10um”
>>> Pn20E = 16,777,216 / Pn210 = 500

- Pn000.1: Control Method Selection

FX3U Instructions Explained
The following are the main instructions used for the FX3U PLC to control the Servo Motor
Zero Return Instruction

- S1: ORG Sensor (near-point signal (DOG) input device numbe)
- S2: Z-Phase signal input ( from Servo Motor)
- D1: Pulse output number
- D2: Rotation direction signal output
Absolute Pulses Output Instruction

- S1: Number of output pulses (Absolute address)
- S2: Output pulse frequency (Speed)
- D1: Pulse output number
- D2: Rotation direction signal output
Increment Pulses Output Instruction

FX3U “Pulse Train Ouput” Example
+ Servo ON/OFF & Zero Return Control

+ Axis Jog Process

+ FX3U Possition Control

Video Tutorial
======
Software and documents for the project
+ Mitsubishi GX Works2 Software Download
+ Yaskawa Servo Software Download
Yaskawa Sigma 7 Manual PDF Download
Password Extract: plc247.com
Please comment and share the article to the community if you find it useful. Subscribe to Youtube channel and Website to read new articles of plc247.com
Thanks and Best Regards!

how about “wiring connection diagram” for sigma 5 CN1 26pin sir?
Sigma 5 CN1 26Pin ? Mechatrolink type ?
Mechatrolink II
sgdv-R7011A
is that type can be controlled like ur?
Not same, need PLC Support Metratrolink II (Keyence, Yaskawa, Omron)
Could you please upload a download link for the program files for FX5U?
I have an article on how to use FX5U to control Yaskawa Sigma 7
sir,i have a question about can i use FX3U-32MR/ES control YASKAWA Sigma 7.or should i use FX3U-32MT/ES control .whitch difference
MR not support control Servo/Step sir