Hello friends, Inovance MD200 inverter is a versatile mini inverter series that is widely applied thanks to its good quality, stable and reliable operation. With good quality, competitive price, MD200 series is the priority choice of quality and economy of every user.
In addition to supporting basic control types such as Terminal and Analog, the Inovance MD200 inverter also has a built-in Modbus or CANLink communication port. Today plc247.com will guide you to control it with HMI Mitsubishi GT2505-VTBD via Modbus RTU protocol.

HMI Mitsubishi & Inovance MD200 “Wiring Diagram”
Below is the Modbus RTU (RS485) communication connection diagram between the Mitsubishi GT2505-VTBD HMI and the Inovance MD200 inverter.

Inovance MD200 Modbus Parameters Setting
In addition to the basic parameters of the inverter installed according to the motor (frequency, current, voltage…) we need to install the following communication parameters

Inovance MD200 Registers Address Mapping


Note: Mitsubishi GOT2000 Holding Registers Address =
“VFD Address (Dec) + 400001“
+ VFD Control Address = 2000 (hex) = 8192 (dec) + 400001 = 408193 (dec)
- Set Word 8193 = 1 >>> Forward Run
- Set Word 8193 = 2 >>> Reverse Run
- Set Word 8193 = 6 >>> Stop
+ Set Frequency Address = 1000 (hex) = 4096 (dec) + 400001 = 404097 (dec)
>>> Frequency Reference = (0 to 10000 dec) ~ (0 to VFD Max Frequency)
- Output Frequency Address = 1001 (hex) = 4097 (dec) + 400001 = 404098 (dec)
- Output Voltage Address = 1003 (hex) = 4099 (dec) + 400001 = 404100 (dec)
- Output Current Address = 1004 (hex) = 4100 (dec) + 400001 = 404101 (dec)
Mitsubishi GT2505-VTBD “Modbus RTU” Configuration
We need to configure the communication parameters of the HMI and the Inovance MD200 to be exactly the same



HMI Programming
+ HMI Design

+ Setting Frequency

+ Forward Run

+ Reverse Run

+ Stop Command

+ Output Frequency Monitoring

+ Output Voltage Monitoring

+ Output Current Monitoring

Project Video Tutorial
======
References
+ HMI Mitsubishi Programming Software Download
+ Inovance MD200 Manual PDF Download
Password Extract: plc247.com
Please share the article to the community if you find it interesting and useful, comment below the article if you have difficulty in implementing this project, plc247.com will reply to you as soon as possible.
Best Regards!