Mitsubishi MR-J4 is one of the most commonly used Servo Motor in the world, good quality and durability are its advantages. Today plc247.com will guide you to control it with Siemens S7-200 PLC in the easiest way.
We need to use Siemens S7-200 PLC model with Transistor Output (DC/DC/DC) to support high-speed pulse generation to control Servo Motor.


Siemens S7-200 & MR-J4-A Servo “Wiring Diagram”
Below is a simple connection diagram between PLC Siemens S7-200 and Mitsubishi MR-J4-A Servo, you can use more function pins after you have mastered the control.

Note: Need to use more resistors to reduce voltage from 24VDC to 5VDC at 2 pins “Pulse and Direction”
Siemens S7-200 “Pulse Train Output” Setting
+ S7-200 PWM/PTO Control Registers

+ S7-200 PWM/PTO Configuration

Mitsubishi MR-J4-A Parameters Setting
We need to install the following main parameters for Mitsubishi MR-J4-A Servo (use MR-Configurator 2 software for easy installation)
- PA1: Servo control mode selection > Set to “1000” to select the position control mode.
- PA6/7: CMX/CDV: Input pulse gain ratio. Used to correct the change of the number of pulses / revolutions when issuing a command from the PLC to the Servo. The default is 1/1, which corresponds to 131072 pulses / revolution
- PA13.PLSS: Selection of control pulse types: Default is 0100, change the following two factors to select pulse input type. Please see the table below to choose the appropriate control method:

You can Copy the same parameters as Project as below

PLC Programming
+ Control “On/Off” Servo Motor

+ Servo Motor Position Control

Project Video Tutorial
======
References
+ Download STEP7 MicroWin V4.9 SP9 Software
+ Download MR-Configurator 2 Mitsubishi Software
If in the process of using PLC Siemens S7-200 to connect and control Mitsubishi Servo, you need any support, please comment below the article, plc247.com will reply to you as soon as when I read comments.
Best Regards!

hello, good morning. How are you?
My machine has a Siemens servo motor and it had a problem. I have the Mitsubishi drive and servo. What would I need to change in the ladder program? Or should I just change the driver and servo and parameterize it?
Thanks
You don’t need to change anything in the program. Just changing the Servo is OK
If we dont use resistor to pulse pin and direction, drive servo will be broken?
Depends on the Servo you use