Drives Inverters Guides PLC Guides

LabView “Modbus RTU” Yaskawa V1000 Tutorial

Written by plc247.com

Yaskawa V1000 inverter is a series of inverters with compact design, easy parameter setting, stable and reliable operation, high efficiency. It can be controlled by keyboard, peripherals as well as Modbus RTU communication via RS485 port

Today plc247.com will use LabView software to control this inverter via RS485 Communication

Computer & Yaskawa V1000 “Wiring Diagram”

We need to prepare 1 cable to convert USB to RS485

Yaskawa V1000 Modbus RTU Settings

In addition to the basic parameters of the inverter, we need to set the communication parameters as shown in the table below

Registers for Control

+ Motor Control Address = 1

  • Set Word 1 = 1 >>> Forward Start
    = 2 >>> Reverse Start
    = 0 >>> Stop

+ Frequency Setting Address = 2

Registers for Monitoring

In this project we read 3 registers consecutively starting from

+ Output Frequency Address = 24 (hex) = 36 (dec)

LabView Modbus Programming

+ Front Panel

+ Block Diagram

Detailed Instruction Video

======

Required document:

Please share the article to the community if you find it useful. Subscribe to Website and Youtube channel to read new articles. Thanks

Best Regards!

About the author

plc247.com

Leave a Comment

DMCA.com Protection Status