Hello friends!
Delta ASDA-B2 Servo Motor is one of the most commonly used servos on the market. The price is extremely cheap but the quality is quite good, which makes it a lot of choice, especially in small machines.
Today plc247.com will guide you to use the Allen-Bradley MicroLogix 1400 PLC to control Servo Delta-B2 by the method “Pulse Train Output – PTO”

MicroLogix 1400 & Delta B2 Servo “Wiring Diagram”
+ Below is the simplest connection diagram to help us control Delta-B2 Servo (You can use other functional pins of Delta B2 if you want)

Delta ASDA-B2 Servo Parameters Setting
Below are the main settings for Delta ASDA-B2 Drive, plc247.com recommends that you install the same as the table below, after you are proficient in the controller, you can change the settings.

PLC MicroLogix-1400 “Pulse Train Output” Setting
Note: MicroLogix 1400 “1766-L32BXB” supports 3 high speed 100kHz pulse output ports, which are Out 2, Out 3, Out 4 pins. The“OUT – Output” default setting is (-1) if you don’t change it, the program will get Error.

PLC Programming
+ Servo “On/Off” Control & Jog Process

+ Axis Position Control

Project Video Tutorial
======
References
+ Download Delta ASDA-B2 Manual PDF
Password Extract: plc247.com
If the download link is broken or you need any assistance in the process of using MicroLogix 1400 Delta B2 Servo controller, please comment below the article, plc247.com will reply you as soon as possible.