Hello friends!
In previous posts, plc247.com has written instructions for you to use PLC Omron to generate pulses to control Yaskawa and Mitsubishi Servo Motors.
Today I will continue to guide you to use the Omron CP1H PLC to program the simplest way to generate pulses to control Step motors. Driver used in Project is DM542 of Leadshine.

Omron CP1H & Stepping Motor “Wiring Diagram”
- Depending on the type of Step Driver, we can control it with 5V or 24V, if controlled by 5V, we need a resistor R=2k2 (Ohm) to reduce the voltage.
- DM542 Driver supports control from 5 to 24V

PLC Omron “Pulse Train Output” Configuration
PLC Omron CP1H supports 4-axis control pulse generation, plc247.com using “Pulse Output 0”

PLC Omron “Pulse Output” Example
+ Step ON/OFF Control & Move Data

+ Axis Position Control

Video Tutorial
======
Recommended Software
If in the process of using Omron CP1H to control Stepping Motor, you have difficulties or need any support, please comment below the article, plc247.com will reply to you as soon as I read the comments.
Best Regards!

I will buy ABB AC500 PLC and make tutorial
Hello,
I will continue with your program “PLC Omron “Stepping Motor” Control Tutorial”, but can I also do this on a CP2E-N? Will it also work with that because I don’t have a speed curve on it. I am new to omron.
Greetings
CP2E-N same sir
Ok thank you
ok thanks
Hi I wanna ask if the omron PLC have to be the transistor output type or it can also work with the relay otuput type??
only Transistor type sir
for example, because you use cp1h, can I use empty cio lets say 200.00 instead use w0.0?
any bit available sir
Hi! Why it wont work with CP1E- n60dt?
Thank for sharing your knowledge
same sir
Guide to absolute position control using stepper motors with Omron PLCs
yes sir