Hello everyone.
In the previous post, plc247.com guided everyone to connect and install the Allen Bradley PowerFlex 525 inverter.
Today I would like to continue to guide you to control the inverter through a very popular communication standard in the industry: Modbus-RTU. And the device used is HMI Weintek MT8071iE
MT8071iE & PowerFlex 525 “Wiring Diagram”
PowerFlex 525 Modbus Parameters Setting
In addition to the basic parameters of the inverter, we need to set the communication parameters as follows:
Register for Control
>>> Motor Control Address = 2000 (Hexa)
- Set Word 2000 = 18 >>> Run Forward
- Set Word 2000 = 34 >>> Run Reverse
- Set Word 2000 = 1 >>> Stop
= 8 >>> VFD Fault Reset
>>> Frequency Setting Address = 2001 (Hexa)
Register for Monitoring
Weintek MT8071iE Modbus Configuration
MT8071iE HMI Programming
+ HMI Interface
+ Frequency Setting
+ Forward Run
+ Reverse Run
+ Stop Run
+ Reset VFD Error
+ VFD Error Status
+ Frequency Output
+ Voltage Output
+ Current Output
Video Tutorial
======
Recommended software and documentation:
- EasyBuilderPro Software for MT8071iE Programming
- PowerFlex 525 VFD Manual PDF Download (Password Extract: plc247.com)
Please comment and share the article if the community if you find this article useful.
Thanks and Best Regards!
Hi
Could you kindly explain to me how you came to find that the run revers is number 34?
Thank you
Please download the inverter’s documentation to read